EVALUATION OF SHAPING EFFICACY AND CANAL CENTERING ABILITY OF RECIPROCATING HANDPIECE WITH STAINLESS STEEL K FILE, NITI K FILE AND WAVEONE USING CBCT.

Authors

  • Sundaresan Balagopal M.D.S., M.Sc., Professor and Head of the Department, Conservative Dentistry and Endodontics, Tagore Dental College and Hospital, Rathinamangalam, Chennai, Tamil Nadu, India
  • Bahavathi Anandhan Hema Sathya M.D.S., Professor and Head of the Department, Conservative Dentistry and Endodontics, Adiparasakthi Dental College and Hospital, Chennai, Tamil Nadu, India
  • C Charanya M.D.S., Senior Lecturer, Conservative Dentistry and Endodontics, Tagore Dental College and Hospital, Rathinamangalam, Chennai, Tamil Nadu, India
  • Vandana James M.D.S., Reader, Conservative Dentistry and Endodontics, Tagore Dental College and Hospital, Rathinamangalam, Chennai, Tamil Nadu, India
  • Vasudevan Navabharathy Post-graduate student, Conservative Dentistry and Endodontics, Tagore Dental College and Hospital, Rathinamangalam, Chennai, Tamil Nadu, India
  • V Abirami M.D.S., Senior Lecturer, Conservative Dentistry and Endodontics, Tagore Dental College and Hospital, Rathinamangalam, Chennai, Tamil Nadu, India

DOI:

https://doi.org/10.32553/ijmbs.v4i7.1323

Keywords:

Shaping efficacy, Canal centering, reciprocating handpiece, NiTi files, WaveOne Gold, CBCT

Abstract

Introduction: Continuously tapered form of root canal and to maintain the original shape and position of the apical foramen is the key element in root canal treatment. However, canal curvature may cause difficulty in instrumentation. Aim: The aim of this study was to evaluate the shaping efficacy and centering ability of reciprocating handpiece with stainless steel (SS) K files and Nickel Titanium (NiTi) K files in 90 degree and WaveOne gold file system in 150 counterclockwise and 30 clockwise reciprocation using cone bean computer tomography.

Materials and methods: Thirty freshly extracted human mandibular molars with fully formed apices were taken for the study and 11 mm of distal roots were used for the study. They were divided into three groups (n=10). All the three groups were instrumented using reciprocating handpiece. The file system used for Group 1, 2 and 3 are SS k file, NiTi K files, and WaveOne gold file respectively.

Statistical analysis: Data was tabulated and One-way analysis of variance (ANOVA) followed by Tukey post hoc honestly significant difference (HSD) test were conducted at p=0.05 significance.

Results: The results revealed significant variations in shaping efficacy and centering ability at various level by all the three file system. A good canal taper and improved shaping efficacy was significantly reported in favor of WaveOne gold reciprocating file.

Conclusion: The WaveOne Gold showed better shaping ability whereas the canal centering ability at the coronal, middle and the apical third were not found uniform for the three tested instrument.

Keywords: Shaping efficacy, Canal centering, reciprocating handpiece, NiTi files, WaveOne Gold, CBCT

Downloads

Published

2020-07-28

How to Cite

Balagopal, S., Sathya, B. A. H., Charanya, C., James, V., Navabharathy, V., & Abirami, V. (2020). EVALUATION OF SHAPING EFFICACY AND CANAL CENTERING ABILITY OF RECIPROCATING HANDPIECE WITH STAINLESS STEEL K FILE, NITI K FILE AND WAVEONE USING CBCT. International Journal of Medical and Biomedical Studies, 4(7). https://doi.org/10.32553/ijmbs.v4i7.1323

Issue

Section

Research Articles

Most read articles by the same author(s)